XHV-43A Diaper Permeability Tester

Product Description of XHV-43A Diaper Permeability Tester

Diapers Permeability Tester Used to test the permeability performance of diapers, such as absorption speed, rewet, leakage.


Test Standards of XHV-43A Diaper Permeability Tester

GB/T 28004.1-2021 Diapers Part 1Infant Diapers

GB/T 28004.2-2021 Diapers Part 2Adult Diapers


Product Features of XHV-43A Diaper Permeability Tester

1. The test solution used for testing is controlled by a peristaltic pump to ensure the stability and repeatability of the addition, with an accuracy of ± 1%.

2. The heating method of the test solution (physiological saline) adopts a water bath heating method and is stored in a glass jar, without any impact on the performance of the test solution.

3. Color touch screen control, English menu, man-machine dialogue mode, convenient to operation.

4. Can be set and test liquid filling volume and flow rate.

5. Electrodes and pumps, can test different types of samples including adults and baby.

6. Diaper Permeability Testing Equipment: Automatically fill liquid, test, weigh.

7. Platinum electrode, good induction and positioning automatically.

8. Adopting stepping motor and high-precision ball screw drive, accurate stroke.

9. Data processing automatically, including average, standard deviation, and coefficient of variation.

10. Thermal printer,for printing of test results quickly.


Technical Parameter of XHV-43A Diaper Permeability Tester

Standard Liquid Module

 

Baby

W

(80±1)mmM1

(85±1)mmM2

(95±1)mmM3

L

(100±1)mmM1

(108±1)mmM2

(125±1)mmM3

Adult

W

(70±1)mmM1

(95±1)mmM2

/

L

(170±1)mmM1

(170±1)mmM2

/

 

Standard Pressure Module

 

Baby

W

(80±1)mmY1

(85±1)mmY2

(95±1)mmY3

L

(100±1)mmY1

(108±1)mmY2

(125±1)mmY3

Adult

W

(70±1)mmY1

(95±1)mmY2

/

L

(170±1)mmY1

(170±1)mmY2

/

 

Sample Base

 

Baby

U- Shaped Sample Base

W

(122±1)mmB1

(135±1)mmB2

(152±1)mmB3

L

(125±1)mmB1

(136±1)mmB2

(154±1)mmB3

Adult

ARC Sample Base

319mm×200mm

 

 

Technci Parameter:

Test Position

1

Control Mode

Touch Screen Control

Range of Timer

0.00 - 9999.99 s

Liquid Addition Device

Deviation of liquid addtion volume ±2mL

Dosing Flow Rate

Baby: (480±5)ml/min

Adult: (720±5)ml/min

Pressurize Pressure

2.0±0.2 KPa, 4.0±0.2 KPa

Liquid Heating Range

RT+5℃-50℃

Weighing Scale

300g, 0.01g

Dimension

1220mm×220mm×500mm

Power Supply

AC220V 50Hz 